Operating principle
The Bimor's driving force, the bimorph, comprises two parallel piezoelectric wafers. Their nature is to expand or contract depending on the direction of the voltage. Therefore, when an alternating current is applied, one wafer expands then contracts while the other contracts then expands, causing the biomorph to bend. Repeating the cycle creates a pumping action, as the diagram below shows.Specifications
Current: 30 mA
Flow Rate: 400 ml/min
Outlet Pressure: 350 mbar
Self-Priming Pressure: 100 mbar
Housing Material: PPS
Bimorph Material: PTFE
Valve / O-Ring: FFKM
Weight: 170 g
Suitable Liquids: Strong Acids, Strong Alkalines, Polar Solvents
Click to download the Technical Specification of BPH 474P 120V